User manual for the ZEN 3-channel X-LMS controller Soft dB inc.
detected on the error signals. The next figure shows the PC interface when the
autonomous test is running:
Figure 19 : Autonomous Mode Tab (Test Autonomous Mode)
During the autonomous mode, the processor in the ZEN unit observes the error signals
and if saturation is detected, the normalized MU is divided by 2 and the control filters are
reset. After multiple saturations, the normalized MU reaches zero and the controller is
stopped.
ZEN User Manual p. 35