Przeglądanie stron 67
65
Frequency (Hz)
Saturation Level
(dB)
Minimum Linear
Level (dB)
Linear Dynamic
Range (dB)
Noise Floor (dB)
120.5 26.3 94.2
16.9
120.5 27.0 93.5
17.5
120.5 27.6 92.9
19.5
120.5 28.3 92.2
19.7
Filter Linearity (High Range)
Frequency (Hz)
Saturation Level
(dB)
Minimum Linear
Level (dB)
Linear Dynamic
Range (dB)
Noise Floor (dB)
132.5 51.5 81.0
7.3
132.5 49.2 83.3
5.3
132.5 47.1 85.4
2.0
132.5 44.2 88.3
7.9
132.5 41.8 90.7
9.3
132.5 39.1 93.4
9.1
132.5 37.1 95.4
10.6
132.5 32.6 99.9
10.6
132.5 31.4 101.1
11.6
132.5 31.0 101.5
11.9
132.5 30.7 101.8
12.7
132.5 30.1 102.4
12.8
132.5 28.7 103.8
12.9
132.5 28.5 104.0
13.5
132.5 28.2 104.3
13.4
132.5 27.2 105.3
13.6
132.5 27.0 105.5
13.6
132.5 26.8 105.7
14.1
132.5 27.1 105.4
14.8
132.5 27.0 105.5
15.4
132.5 27.4 105.1
16.2
132.5 27.6 104.9
17.0
132.5 28.1 104.4
18.0
132.5 30.1 102.4
19.1
132.5 30.4 102.1
20.1
132.5 31.8 100.7
21.0