Soft-db Opus Suite Building Vib Module Instrukcja Użytkownika Strona 13

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 33
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 12
5 QuickStart
The Opus Building Vib Module monitors the vibration time signal from a triaxial accelerometer .
When a specified vibration threshold is measured, an event record is triggered. Then, the event
recordisanalysedtoidentifythepeakforeachaxisandassociatedparameters.
Eacheventrecordcontainsthesimultaneousacceleration,velocityanddispl
acementwaveformsfor
eachaxisandtheacousticwaveforms(TimeSignalandSoundPressureLevels(SPL)).
Step1 ConnectionsandSetup
Connectthemicrophone toinput1andthethreeaccelerometersX,YandZaxistoinputs2,3and4
respectively.
Forpurposesofexample,fastentheaccelerometertoatabl
etop.
Step2 RuntheMeasurement
Clickonthe
buttontostartthemeasurement.Atthispoint,youshouldseetherunning
waveformonthewaveformsgraphsattheleftoftheinterface.
Step3 GenerateEvents
Withtheaccelerometerfastenedtoatabletop,gentlyhitthetabletopwithyoufisttogeneratea
vibrationevent.
Ifthevibra
tionsignalscausedbythevibrationeventwereabovethetriggerlevel,aneventrecording
hasbeentriggered.The
indicatorislightonduringtheeventrecording.
Whenoneeventhasbeenrecorded,itisanalysedtoidentifythepeakinformation.Itisthenadded
anddisplayedontheeventtableandonthespectrum.
Ifanothervibrationeventoccurs,itwilltriggeranothereventrecording.
Step4 StoptheMea
surement
Once the measurement process is completed, click on the
button to stop the
measurement.
OpusBuildingVibUserGuideV1.1b 9